registers.txt: update M525 info about battery

This commit is contained in:
Peter Wu
2013-04-25 20:00:22 +02:00
parent a52d34aa52
commit 9269ba6215

View File

@@ -288,15 +288,9 @@ Send report_id=10 short device=FF RECV type=80 SET_REG reg=B2
report_id=10 short device=FF RECV type=4A NOTIF_RECV_LOCK_CHANGED params=00 00 00 00
Somewhere in the below stream is the battery condition of the M525 mouse (good).
Recv report_id=10 short device=01 DEV1 type=41 NOTIF_DEVICE_PAIRED params=04 52 13 40
Recv report_id=10 short device=FF RECV type=80 SET_REG reg=02 CONNECTION_STATE params=00 00 00
Send report_id=10 short device=FF RECV type=83 GET_LONG_REG reg=B5 PAIRING_INFO params=30 00 00
Recv report_id=11 long device=FF RECV type=83 GET_LONG_REG reg=B5 PAIRING_INFO params=30 DA FA 33 5E 04 00 00 00 01 00 00 00 00 00 00
Recv report_id=10 short device=01 DEV1 type=41 NOTIF_DEVICE_PAIRED params=04 92 13 40
Recv report_id=20 unkn device=01 DEV1 type=42 NOTIF_CONNECTION_STATUS params=00 00 00 00 00 00 00 00 00 00 00 00
Send report_id=10 short device=FF RECV type=83 GET_LONG_REG reg=B5 PAIRING_INFO params=30 00 00
Recv report_id=11 long device=01 DEV1 type=05 params=00 01 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00
Recv report_id=11 long device=FF RECV type=83 GET_LONG_REG reg=B5 PAIRING_INFO params=30 DA FA 33 5E 04 00 00 00 01 00 00 00 00 00 00
It could also be that there is no battery information at all and that SetPoint
is faking the information. I have tried brand-new Duracell batteries and the
output is still the same.
Send report_id=10 short device=01 DEV1 type=00 params=05 00 03 00
Recv report_id=11 long device=01 DEV1 type=00 params=05 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Send report_id=10 short device=01 DEV1 type=02 MOUSE params=05 00 00 00
@@ -307,8 +301,12 @@ Send report_id=10 short device=01 DEV1 type=04 SYSTEM_CONTROL params
Recv report_id=11 long device=01 DEV1 type=04 SYSTEM_CONTROL params=05 5A 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Send report_id=10 short device=01 DEV1 type=0B params=15 01 00 00
Recv report_id=11 long device=01 DEV1 type=0B params=15 01 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Recv report_id=20 unkn device=01 DEV1 type=02 MOUSE params=00 00 00 00 00 FF 00 00 00 00 00 00
Recv report_id=20 unkn device=01 DEV1 type=02 MOUSE params=00 00 00 00 00 FF 00 00 00 00 00 00
The mouse got some messages when SetPoint is closed:
Send report_id=10 short device=01 DEV1 type=0B params=15 00 00 00
Recv report_id=11 long device=01 DEV1 type=0B params=15 00 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Send report_id=10 short device=01 DEV1 type=04 SYSTEM_CONTROL params=05 00 00 00
Recv report_id=11 long device=01 DEV1 type=04 SYSTEM_CONTROL params=05 5A 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Back to alive (very, very red battery for keyboard):
Recv report_id=10 short device=02 DEV2 type=41 NOTIF_DEVICE_PAIRED params=04 A1 10 20